LYJ Series Mono-blocks for Cold Storage
1. Product description
We have 2 sub series product of LYJ mono blocks, one is wall mounting type, and the other is roof top type or ceiling mounting type one. This manual is specially made for our roof top mono block series products, which can be used for small cold rooms of temperature of -5℃~5℃ or - 15℃~-20℃, in hotels, restaurants, medicines, agricultural, chemicals industries all other place where cold storage is needed.
2. Features
3. It is compact in structure, save installation space. That integrates evaporator, condenser, compressor, electrical control units into one compact body.
With world famous brand hermetic compressors and refrigeration parts for all products;
Heat exchangers with high efficient in grooved copper tube and aluminum fins;
Intellectual controls with automatic temperature set, temperature control.
Protection devices for over loading, sub-heating, lack of phase, high & low pressure etc.
Easy, labor saving for installation;
Hot gas defrosting
Refrigerant R404a
4. Specifications
4.1 Wall type
Wall type Specifications
Model |
LYJ33MY-P |
LYJ50MY-P |
LYJ63MY-P |
LYJ100MY-P |
LYJ125MY-P |
LYJ175MY-P |
LYJ200MY-P |
LYJ275MY-P |
LYJ350MY-P |
|||||||
Cap (W) |
530 |
810 |
1050 |
1560 |
2230 |
2950 |
3250 |
4400 |
5200 |
|||||||
Input (KW) |
0.68 |
0.85 |
1.1 |
1.3 |
1.75 |
2.52 |
2.61 |
3.33 |
4.2 |
|||||||
Power supply |
220V/50HZ |
380V /50HZ |
||||||||||||||
Tem range (℃) |
0~5 |
|||||||||||||||
Cond fan(W) |
1×75 |
1×75 |
1×75 |
1×80 |
1×80 |
1×155 |
1×155 |
2×80 |
2×80 |
|||||||
Evap fan(W) |
1×75 |
1×75 |
1×75 |
1×80 |
1×80 |
1×155 |
1×155 |
2×80 |
2×80 |
|||||||
Defrost type |
Electrical Heating |
|||||||||||||||
Expansion type |
Expeansion Valve |
|||||||||||||||
Refrigerant |
R404A |
|||||||||||||||
WT(kg) |
57 |
60 |
62 |
87 |
90 |
117 |
120 |
150 |
155 |
|||||||
Model |
LYJ50LY-P |
LYJ63LY-P |
LYJ100LY-P |
LYJ150LY-P |
LYJ200LY-P |
LYJ300LY-P |
LYJ400LY-P |
|||||||||
Cap (W) |
550 |
660 |
750 |
1050 |
1580 |
2060 |
3100 |
|||||||||
Input (KW) |
0.63 |
0.71 |
1.04 |
1.35 |
2.01 |
2.63 |
3.26 |
|||||||||
Power supply |
220V/50HZ |
380V /50HZ |
||||||||||||||
Tem range (℃) |
-18~-20 |
|||||||||||||||
Cond fan(W) |
1×75 |
1×75 |
1×80 |
1×80 |
1×155 |
1×155 |
2×80 |
|||||||||
Evap fan(W) |
1×75 |
1×75 |
1×80 |
1×80 |
1×155 |
1×155 |
2×80 |
|||||||||
Defrost type |
Electrical Heating |
|||||||||||||||
Expansion type |
Expansion Valve |
|||||||||||||||
Refrigerant |
R404A |
|||||||||||||||
WT(kg) |
60 |
62 |
88 |
92 |
123 |
128 |
160 |
|||||||||
Note: The Cap test condition of LYJ××MY is: Te/Tcon: -7℃/45℃. The Cap test condition of LYJ××LY is: Te/Tcon: -25℃/45℃.
Overall and installation dimensions
1)Overall sizes
2)Installation sizes:
3)Overall and installation sizes:
Model |
LYJ33MY-P |
LYJ50MY-P |
LYJ63MY-P |
LYJ100MY-P |
LYJ125MY-P |
LYJ175MY-P |
LYJ200MY-P |
LYJ275MY-P |
LYJ350MY-P |
A |
490 |
490 |
490 |
620 |
620 |
800 |
800 |
1090 |
1090 |
B |
1000 |
1000 |
1000 |
1020 |
1020 |
1020 |
1020 |
1020 |
1020 |
C |
730 |
730 |
730 |
765 |
765 |
805 |
805 |
805 |
805 |
E |
340 |
340 |
340 |
390 |
390 |
390 |
390 |
390 |
390 |
F |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
L |
445 |
445 |
445 |
575 |
575 |
755 |
755 |
1045 |
1045 |
H |
360 |
360 |
360 |
455 |
455 |
455 |
455 |
455 |
455 |
Model |
LYJ50LY-P |
LYJ63LY-P |
LYJ100LY-P |
LYJ150LY-P |
LYJ200LY-P |
LYJ300LY-P |
LYJ400LY-P |
A |
490 |
490 |
620 |
620 |
800 |
800 |
1090 |
B |
1050 |
1050 |
1070 |
1070 |
1070 |
1070 |
1070 |
C |
730 |
730 |
765 |
765 |
805 |
805 |
805 |
E |
340 |
340 |
390 |
390 |
390 |
390 |
390 |
F |
150 |
150 |
150 |
150 |
150 |
150 |
150 |
L |
445 |
445 |
575 |
575 |
755 |
755 |
1045 |
H |
360 |
360 |
455 |
455 |
455 |
455 |
455 |
4.2 Roof top type
Roof top type Specifications
Model |
LYJ50MY-T |
LYJ63MY-T |
LYJ100MY-T |
LYJ125MY-T |
LYJ175MY-T |
LYJ275MY-T |
LYJ350MY-T |
Capacity (W) |
810 |
1050 |
1560 |
2230 |
2950 |
4400 |
5200 |
Input (KW) |
0.85 |
1.1 |
1.3 |
1.75 |
2.52 |
3.33 |
4.2 |
Power supply |
220V/50HZ |
380V /50HZ |
|||||
Temperature |
0~5℃ |
||||||
Condenser fan(W) |
1×75 |
1×75 |
1×80 |
1×80 |
1×80 |
2×80 |
2×80 |
Evaporator fan(W) |
1×75 |
1×75 |
1×80 |
1×80 |
1×80 |
2×80 |
2×80 |
Defrost type |
Hot gas |
||||||
Throttling |
Expansion Valve |
||||||
Refrigerant |
R404A |
||||||
|
73 |
75 |
118 |
122 |
145 |
190 |
195 |
Model |
LYJ50LY-T |
LYJ63LY-T |
LYJ100LY-T |
LYJ150LY-T |
LYJ200LY-T |
LYJ300LY-T |
Capacity (W) |
550 |
660 |
750 |
1050 |
1580 |
2060 |
Input (KW) |
0.63 |
0.71 |
1.04 |
1.35 |
2.01 |
2.63 |
Power supply |
220V/50HZ |
380V /50HZ |
||||
Temperature |
-18~-20℃ |
|||||
Condenser fan(W) |
1×75 |
1×75 |
1×80 |
1×80 |
1×80 |
2×80 |
Evaporator fan(W) |
1×75 |
1×75 |
1×80 |
1×80 |
1×80 |
2×80 |
Defrost type |
Hot gas |
|||||
Throttling |
Expansion Valve |
|||||
Refrigerant |
R404A |
|||||
|
73 |
75 |
118 |
122 |
155 |
168 |
Note: The Cap test condition of LYJ××MY is: Te/Tcon: -7℃/45℃. The Cap test condition of LYJ××LY is: Te/Tcon: -25℃/45℃.
℃. The capacity test condition of LYJ××LY is: Te/Ta: -25℃/32℃.
Overall and installation size
Model |
LYJ50MY-T |
LYJ63MY-T |
LYJ100MY-T |
LYJ125MY-T |
LYJ175MY-T |
LYJ275MY-T |
LYJ350MY-T |
A |
580 |
580 |
760 |
760 |
760 |
1140 |
1140 |
B |
1031 |
1031 |
1251 |
1251 |
1251 |
1251 |
1251 |
C |
371 |
371 |
471 |
471 |
471 |
471 |
471 |
E |
481 |
481 |
551 |
551 |
551 |
551 |
551 |
F |
150 |
150 |
150 |
150 |
150 |
150 |
150 |
L |
482 |
482 |
662 |
662 |
662 |
1042 |
1042 |
H |
452 |
452 |
602 |
602 |
602 |
602 |
602 |
Model |
LYJ50LY-T |
LYJ63LY-T |
LYJ100LY-T |
LYJ150LY-T |
LYJ200LY-T |
LYJ300LY-T |
A |
580 |
580 |
760 |
760 |
760 |
1140 |
B |
1031 |
1031 |
1251 |
1251 |
1251 |
1251 |
C |
371 |
371 |
471 |
471 |
471 |
471 |
E |
481 |
481 |
551 |
551 |
551 |
551 |
F |
150 |
150 |
150 |
150 |
150 |
150 |
L |
482 |
482 |
662 |
662 |
662 |
1042 |
H |
452 |
452 |
602 |
602 |
602 |
602 |